Network Code
The seismic data is expected to be globally distributed, which means the codes need to be internationally registered. The current approach is to use the already registered NZ network code for all recorded public data. Otherwise the internal XX code is used for temporary or private data that will not, or cannot, be exported.
Station Code
The National Seismograph Network station codes have, over time, developed into three letter codes with generally the last letter being a Z. The exceptions being the very oldest installations such as WEL. The trailing Z has generally made registering station codes easier.
In the past, the National Strong Motion Network recording sites tended to have a numbering system with a three digit prefix and a trailing letter. Equipment at these sites were mostly analogue, with manually digitized data. The current National Strong Motion Network site code naming convention is to use four letter codes, with all data recorded digitally.
For National Seismograph Network sites they generally follow the convention of having three letters, with a last being a Z. Other Regional Seismograph Networks use a four letter code, again with the last letter being a Z. The letter prior to this can also represent the regional or geographic network the station is in. Exceptions to this are generally the very oldest sites which pre-date the addition of the trailing Z. All other sites use four letter codes with the trailing letter giving some indication of the network or geographical location. For older sites the suffixes tend to be the initial letter of the original network code as outlined above.
For any future major instrument expansions the use of five letter station codes may be needed.
Location Code
There are two types of location codes used and are related to either sensor placement or the recording datalogger. The location code is primarily used to distinguish between multiple sensors installed at a single recording site where the same station code is used. The location code is also used to distinguish between the SOH records taken from any dataloggers which may be installed at the same site.
The SEED format requires that the location code, if used, be case independent (upper-case), and made up only of the standard letters A-Z, numbers 0-9, or the space character. There are no related SEED usage conventions although originally the global networks tended to use the location code to distinguish between sensors that were installed at various depths down boreholes from those installed on the surface.
The current convention is used to both indicate sensor type and location.
- 0? - Reserved for datalogger SOH channels
- 1? - Reserved for weak motion sensors
- 2? - Reserved for strong motion sensors
- 3? - Reserved for acoustic or pressure sensors
- 4? - Reserved for water level pressure sensors
- 5? - Reserved for geomagnetic sensors
- 6? - Reserved for strain or displacement sensors
- 7? - Reserved for wind measuring sensors
- 8? - Reserved for temperature sensors
There is an informal convention of using 01 for the primary datalogger (generally weak-motion) and 02 for the secondary datalogger (generally strong motion). This setup has been maintained for sites with only strong-motion recorders as it makes maintaining instrument configurations easier.
Testing, or non-production, dataloggers will have codes using the sequence: 0Z, 0Y, 0X, ... etc. They should also use a similar sensor location sequence depending on sensor type, e.g. 1Z, 1Y, 1X ... etc.
Channel Code
Channel codes generally follow the SEED conventions, although some channel codes preceded the conventions and have not been updated.
Apart from a small number of state of health (SOH) channels, the first letter of the code represents a combination of sampling rate and sensor bandwidth, e.g.
U (Ultra Long Period sampled at 0.01Hz, or SOH sampled at 0.01Hz)
V (Very Long Period sampled at 0.1Hz, or SOH sampled at 0.1Hz)
L (Broad band sampled at 1Hz, or SOH sampled at 1Hz)
B (Broad band sampled at between 10 and 80 Hz, usually 10 or 50 Hz)
S (Short-period sampled at between 10 and 80 Hz, usually 50 Hz)
H (High Broad band sampled at or above 80Hz, generally 100 or 200 Hz)
E (Extremely Short-period sampled at or above 80Hz, generally 100 Hz)
The second letter represents the sensor type, e.g..
H (Weak motion sensor, e.g. measuring velocity)
N (Strong motion sensor, e.g. measuring acceleration)
L (Low gain sensor, usually velocity)
M (Mass position, used for monitoring broadband sensors)
D (Barometer or pressure sensor)
K (Temperature sensor)
A (Tiltmeter)
F (Geomagnetic sensor)
T (Water level sensor)
The third letter either represents the sensor orientation or a processing stage.
Z,N,E (Three component sensor aligned to North)
Z,1,2 (Three component sensor with non-aligned orientation, generally used for borehole sensors or strong motion recorders)
X,Y,Z (Three component sensors with site specific orientations, generally used for building arrays)
U,V,W (Three component sensors with non-standard orientations, generally used for mass positions of broadband sensors)
Z (Single component vertical sensor, or pressure sensor used to measure height).
F (Sensors that have no orientation, such as pressure sensors or geomagnetic fields)
H (Sea level streams which have been corrected to height, generally used for processing)
T (Sea level streams which have been de-tided, generally used for processing)
Example Channels
Data Channels
Data Quality Channels
State of Health Channels